| SERIES 100 (Flange lock-up) |
| TYPE |
LEAD OR TERMINALS |
OTHER DESCRIPTION |
 |
| 100 |
Studs |
No Terminal Box |
| 101 |
Studs |
With Terminal Box 1-3/4" High |
| 102 |
Studs |
With Low Profile Box 1" High |
| 103 |
Armor |
Strain Relief Bracket Straight |
| 104 |
Armor |
Strain Relief Bracket 90 Deg. Bend |
| 105 |
Braid |
Strain Relief Bracket Straight |
| 106 |
Braid |
Strain Relief Bracket 90 Deg. Bend |
| SERIES 200 (Barrel nut clamping) |
| 200 |
Studs |
No Terminal Box |

 |
| 201 |
Studs |
With Terminal Box 1-3/4" High |
| 202 |
Studs |
With Low Profile Box 1" High |
| 203 |
Armor |
Strain Relief Bracket Straight |
| 204 |
Armor |
Strain Relief Bracket 90 Deg. Bend |
| 205 |
Braid |
Strain Relief Bracket Straight |
| 206 |
Braid |
Strain Relief Bracket 90 Deg. Bend |
| SERIES 300 (Latch and trunnion) |
| 300 |
Studs |
No Terminal Box |
 |
| 301 |
Studs |
With Terminal Box 1-3/4" High |
| 302 |
Studs |
With Low Profile Box 1" High |
| 303 |
Armor |
Strain Relief Bracket Straight |
| 304 |
Armor |
Strain Relief Bracket 90 Deg. Bend |
| 305 |
Braid |
Strain Relief Bracket Straight |
| 306 |
Braid |
Strain Relief Bracket 90 Deg. Bend |
Specifications |
Temperature Up to 1400 Deg. F
Watt Density Up to 45W/Sq. In.
Voltage Up to 480 V (single or three phase)
Resistance-Tolerance NEMA Standard plus 5%, Minus 10%
Wattage Tolerance NEMA Standard plus 5%, Minus 10%
Maximum Amperage 25/Circuit
Insulation Available in both standard ¼" and insulation Plus ½" construction
2" dia. And up; 1-1/2" width and up (in ½" increments)
Terminals ¼-20 post terminals standard
Sheath Stainless steel
Lock-up Flange type standard
Maximum ID Consult factory
Standard width increments ½"
Standard gap when tightened ¼"
Thickness w/1/4" insulation 5/8"
Thickness w/1/2" insulation 7/8" |
Options
Where flexible leads in armor or braid are specified, Omega recommends the use of post terminal in box with leads off box.
IP Add if you want the "Insulation Plus"
A Armored Cable (BX)
B Braided Wire
C Leads Wire, No Braid or Armor
D Lead exiting out of edge of heater, through porcelain insulator
E Terminal Connectors on studs - Ring lugs
F Partial Coverage
G Thermocouple hole in element area |
H Thermocouple hole in gap area, notched
I Inner Liner
J Twist Lock Plug on leads
K Wider than normal gap, specify
L Ground stud
M Dual Voltage - for bands 2-1/2" or more in width
N Four wire construction
O Overlapping shell on gap area |
Note:
A) Latch and trunion has quick release spring loading, suggested for ceramic band with a 12" diameter or greater.
B) Terminal boxes and stud terminals are normally located 180 degrees opposite the gap. |
|
WHEN ORDERING, PLEASE SPECIFY:
Quanity
Inside diameter & width
Voltage - on 2 piece bands we suggest each piece be rated at half the operating voltage, please specify total voltage
Wattage - on 2 piece bands please specify total wattage
Basic construction and options
Serial no. (If known or previously ordered)
Gap (if other than factory minimum)
Lead length (If other than std. 12") |
| Maintenance and trouble shooting for prolonging heater life |
1. Regulate Voltage. A 10% variation in voltage results in a 20% variation in power.
2. When attaching the lead wire to the terminals, excessive turning pressure can cause breakage of the terminal resistance wire.
3. A ¼" gap should be maintained at the opening when operating. Retightening is not normally required, however, if the operating temperature is changed the clamp bolt should be checked. |
|