STS Offers:
Thermal Process Solutions
Industrial Heating Applications
Heating Elements, System Controls
CCR #: 569T64
|
   |
|
- Mica Heater Bands
- Ceramic Band Heaters
- Insulation Plus Heaters
- Ultra-Thin Ceramic Band Heaters
- Air Cooled Ceramic Band Heaters
Mica Heater Bands
Fax-Back Data Sheet Basic Mica Band Construction Nozzle Heater Bands

Mica Band Heater Catalog
BASIC CONSTRUCTIONS
"Advantage Thin Line" Mica Bands
These Heaters were designed primarily as economical mica band heaters in nozzle and narrow width sizes. In the range of sizes recommended in our price list these heaters will perform as well as any mica band currently available. Although these heaters can be made in sizes other than those listed, Omega's standard line of mica bands are recommended for larger size heaters as well as higher temperature and high voltage applications.
Optional Features:
|
A Flexible armor (BX) installed over flexible leads.
B Metal braid installed over flexible leads.
C flexible leads - asbestos and fiberglass insulated nickel or nickel clad conductor. Installed with 2" fiberglass boot.
D Low profile band, presize for slip fit by installation of punch lock straps.
E Terminal box.
F Flexible armor in right angle bracket. |
G Thermocouple hole.
H Button Terminals
I Appliance pins.
J Twist lock plug installed on leads.
K Extra wide gap, specify.
L Grounding stud.
M Dual voltage, specify.
N Stainless steel sheath.
O Low profile strap. Specify this coupon only if desired on sizes where not normally supplied.
P Post terminals |
When Ordering Please Specify:
1. QUANTITY
2. INSIDE DIAMETER
3. WIDTH
4. VOLTAGE - on two piece band we suggest each piece be rated at half the operating voltage.
Please specify total voltage.
5. WATTAGE - on two piece bands please specify total wattage.
6. BASIC CONSTRUCTION AND OPTIONS DESIRED - see below
7. SERIAL NUMBER - if known or previously ordered.
8. GAP, if other then factory determined minimum.
9. LEAD LENGTH, if other than standard 12 inches.
*ON FLANGED BANDS, when post terminals are specified at the same end of band, they will normally be located as follows: Bands under 2" wide-Post terminals will be placed tandem, around circumference of band. Bands 2" wide and over-Post terminals will be placed across width of band.
|
|
|
Standard Ceramic Band Heaters
Plastic processing requires high operating temperatures and fast production rates. We have designed ceramic band heaters to meet these demands. These heater are, in effect, high temperature electric furnaces capable of very efficient heat transfer by radiation, conduction and convection. Built-in insulation minimizes unwanted temperature changes along the barrel.
Other types of band heaters are primarily conductive, requiring an intimate fit with components being heated. Grooves or other surface irregularities form voids under the bands, resulting in hot spots and premature heater failure.
Ceramic bands are recommended here because efficient heat transfer is not affected by irregular surfaces or loose fit. At higher watt densities they can be used in wider increments than other heaters. This means you can reduce the number of bands used and simplify wiring.
"THE PREFERRED CHOICE OF OEM’S"
- Stainless steel sheath
Resists rust and high temperatures, and provides firm mechanical support. Easily wraps around barrel due to fluted construction.
- Thermal insulation
¼ inch of ceramic fiber prevents heat loss, thereby lowering energy costs.
- Ceramic coil supports
Designed for their dielectric and thermoconductive characteristics, the interlocking feature provides flexibility so band wraps easily around barrel.
- Nickel-chrome heating coil, precision wound, helical construction gives extended service. A heavier weight than found in mica or other conventional heaters.
Specifications | Common Sizes and Ratings
Download Fax-Back Datasheet
|
Ultra-Thin Ceramic Band Heaters
3/8" Thick, 3/16" thermal insulation, up to 65 watts/sq. in.
High performance heater band for processing high temperature engineering resins. The first improvement in ceramic heaters since the introduction of"Insulation Plus"TM in 1975. "Ultra-Thin" heater bands have the same basic construction as our standardceramic heaters except they are much thinner and have a high ratio of thermal to electrical insulation. The thin ceramic insulation’ used results in a lower mass construction, which improves response to control and minimizes temperature lag and overshoot.

The backside thermal insulation is highly efficient and results in minimal heat loss and lower sheath temperature. The "Ultra-Thin" has averaged 100 deg. F lower sheath temperature when tested against other high temperature heaters at 600 deg. F cylinder temperatures. The "Ultra-Thin" without thermal insulation and with a perforated sheath is ideally suited for air cooled systems.
"Ultra-Thin" heaters are constructed of all high temperature materials. The heater element itself is computer designed for maximum wire size which results in a long service life. Developed primarily for high temperature, high watt density plastic processing machinery, this premium performance heater can be used in many other applications.
|
Specifications:
Insulation - 3/16" thick thermal insulation (ceramic fiber)
Sizes - Minimum 1D 1-1/2" (38.1mm) 1" wide and up
Terminals - Post Terminals Standard ( 10-24 Thread or 1/4"-20 Thread)
Sheath - Stainless Steel
Lock-up - Flange or Barrel Nut Standard
Standard Gap - 1/4" when tightened
Metric sizes available
Wall Thickness - 11/32" (+1/32", -.00)
Temperature - Up to 1400 Deg. F
Watt Density - Up to 65W/Sq. in. (9.9 W/C2)
Voltage - Up to 480 V (Single or three phase)
Resistance-Tolerance +10%-5%
Wattage Tolerance +5%-10%
Maximum Amperage - 20/Circuit |
Options:
A - Armored Cable (BX)
B - Braided Over Leads
C - Plain Leads
D - Right Angle Armor
E - Right Angle Brald
F - Partial Coverage
G - T/C Hole (specify location)
H- Inner S.S. Liner
I - Ground Stud or Wire
J - Dual Voltage
K- Latch-Trunnion Lock-Up
L- Overlap on shell at gap
M - Standard Terminal Box
N- Low Profile (1" high) Terminal Box
O - Ceramic Terminal Caps
P - Quick Disconnected High Temperature Plugs For other options consult factory! |
Special Note:
These are completely flexible radiant heaters. Heavy clamping pressures are not required regardless of heater size. No need for hinged, two piece, or expandable designs associated with mineral insulated (MI), mica or other conduction type heaters.
Download Fax-Back Datasheet
|
Air Cooled Ceramic Band Heaters
Air Cooled Ceramic Heater Assembly For Extruder Barrels
This new super-efficient and economical air cooled ceramic heater bands are designed for use on extrusion machinery or on any heat/cool operation.
The new heater bands feature 63% open perforated metal sheath, which assures maximum surface area exposure. They also provide the user with a more economical operation, via a rapid heat-up and cool-down feature. Their "Black Star" coating further increases efficiency. Advantages of air cooled vs. Liquid cooled operation include: lower cost, replaceable heaters, low maintenance, no leak problems, and close temperature control.
The new air cooled ceramic heater bands are available in various sizes to either accommodate new designs or to replace less efficient, more expensive cast aluminum heaters.
|
Specifications:
Temperature - Up to 1400 Deg. F
Watt Density -Up to 45 W/Sq. In.
Voltage - Up to 480 V (single or three phase)
Resistance -Tolerance NEMA Standard plus 10% Minus 5%
Wattage Tolerance - NEMA Standard plus 5%, Minus 10%
Maximum Amperage - 25/Circuit
Sizes - 2" dia. And up: 1-1/2" width and up (in 1/2" increments
Terminals - 1/4"-20 post terminals standard
Sheath - Aluminized steel
Lock-up - Flange type steel
Maximum ID - Consult factory
Standard width increments -1/2"
Standard gap when tightened - 1/4"
Thickness - 1/2" |
Options:
A - Armored Cable (BX)
B - Braided Wire
C - Lead Wire, No Braid or Armor
D - Terminal Connectors on studs - Ring lugs
E - Partial Coverage
F - Thermocouple hole in element area
G - Thermocouple hole in gap area, notched
H - Twist Lock Plug on leads
I - Wider than normal gap, specify
J - Ground stud
K - Dual Voltage - for bands 2-1/2" or more in width
Note: A) Terminal boxes and stud terminals are normally located 180 degrees opposite the gap. |
Download Fax-Back Datasheet
|
|